List six late potential complications of PICC line placement.
List six late potential complications of PICC line placement.
Occlusion of catheter (best avoided with frequent flushing
Loss of position at cavoatrial junction
Line fracture
Local infection at puncture site
Thrombophlebitis (3%-10%)
Sepsis (1%-3%)